Use and characteristics of artificial climate chambers - Huaqiang Electronic Network

Probe domestic switch needle KG-300K needle head diameter is 3.0mm normally open switch needle
1206 yellow LED lamp beads 1206 yellow light patch led yellow light LED yellow light

Use and characteristics of artificial climate chamber

Source: Hangzhou Jutong Electronics Co., Ltd.

Artificial climate chamber

It is a high-precision hot and cold thermostat with illumination and humidification function, providing users with an ideal artificial climate experimental environment. It can be used for plant germination, seedling, tissue, microbial culture; feeding of insects and small animals; water analysis

BOD

Determination and other artificial climate tests. It is an ideal test equipment for the production and scientific research departments of biological genetic engineering, medicine, agriculture, forestry, environmental science, animal husbandry, and aquatic products.

use

Artificial climate chamber

Suitable for plant growth and tissue culture, seed germination, seedling, microbial culture test; feeding of small insects; water quality monitoring

BOD

Determination; medicinal materials, wood, building materials aging and service life testing, as well as other uses of lighting, constant temperature, constant humidity special test equipment. Structural features: High-precision hot and cold thermostat with illumination and humidification. Using advanced microcomputer programmable technology to control temperature, multiple parameters can be set

(

Including temperature, humidity, and illuminance

)

Simulate the natural climate. The lighting uses a special high-intensity fluorescent lamp. Light-touch adjustable switch for light and flexible.

led

Digital display, adjustable in multiple modes and easy to operate.

Artificial climate chamber

main feature

1

, multi-window digital display.

2

Full computer control,

1-30

Segment programmable, can be set

30

Group different control parameters.

3

Optional

RS485

The communication interface realizes communication with the host computer and records the running data in real time.

4

Temperature adoption

PID

Control method, high temperature control accuracy.

5

With power-down memory function, the instrument can continue to run from the breakpoint after power-on.

6

It has super UV sterilization function to ensure a pure culture environment.

7

The aluminum alloy frame is light and beautiful and never rusts. It not only has ultra-warm sensor abnormal protection function, but also has independent air duct over-temperature protection device, double protection, which provides a guarantee for the safety of instruments and samples.

Artificial climate chamber

Technical Parameters

1

Temperature control range:

5

°C--

50

°C (no light)

10

°C--

50

°C (with light)

2

Temperature fluctuation: ±

0.5 - 1.0

°C Dehumidification temperature fluctuation: ±

0.5 - 2.0

°C

3

Temperature uniformity: ±

1.0

°C

4

, humidity control range:

50-95% RH

5

Illuminance

3000Lx/12000Lx/22000Lx

Two-sided illumination

,

Five levels are adjustable.

6

,

1-30

Period programmable control, each segment

0-99

Hours can be set

7

Volume:

150L

,

250L

The difference between artificial climate chamber and artificial climate chamber

1

The heating method is different. The general climate chamber is heated by natural sunlight, and the "greenhouse effect" of glass or plastic is used to heat up, and the temperature rise of the artificial climate chamber is the thermal convection method combined with electric furnace wire and blower.

2

Different size

3

The uniformity of temperature and the accuracy of measurement, the operability of the climate chamber is far superior to the climate chamber.

Artificial climate chamber

use:

Artificial climate chamber: crop breeding, growth, etc.

Artificial climate chamber: precise biological culture, because the airtightness is better, it is also suitable for microbial culture and insect feeding.

occasion:

An agriculture

,

a research laboratory and hospital

Use and characteristics of artificial climate chamber Reference: Hangzhou Jutong Electronics Co., Ltd.

Digital Timer Switch Socket

Instruction Manual

1. Features

Clock display, 10 sets of adjustable timed power control, randomized power control, manual switch and optional DST setup.

2. First time charging

This timer contains a rechargeable battery. It is normal that the new/old model runs out of battery if it wasn`t being charged for a long period of time. In this case, the screen will not turn on.

To charge : simply plug the timer to a power outlet. The charging time should take at least 15 minutes.

If the screen doesn`t light up or displays garbled characters, simply reboot the system by pressing the [RESET" button.

3. Set clock


Hold [CLOCK" button and [WEEK" button to adjust week.

Hold [CLOCK" button and [HOUR" button to adjust hour.

Hold [CLOCK" button and [MINUTE" button to adjust minute.

Hold [CLOCK" button and [TIMER" button to select 12 hour/24 hour display.

Hold [CLOCK" button and [ON/AUTO/OFF" button to enable/disable DST (daylight-saving-time).

4. Set timer

Press [TIMER" button, select and set timer. Setting rotation : 1on, 1off, 2on, 2off, ...... , 10on, 10off.

Press [HOUR" button to set hour for timer.

Press [MIN" button to set minute for timer.

Press [WEEK" button to set weekday for timer. Multiple weekdays can be selected. ex: if selected [MO", the timer will only apply on every Monday; if selected [ MO, WE, FR", the timer will apply on every Monday, Wednesday and Friday.


Press [RES/RCL" button to cancel the selected on or off timer. The screen will show "-- -- : -- --" , the timer is canceled.

Press [RES/RCL" button again to reactivate the timer.


When timers are set, press [CLOCK" to quit timer setting and return to clock.

5. Random function


Press [RANDOM" button to activate random function, press again to cancel function.

System only runs random function when [AUTO" is on.

Random function will automatically start the timer from 2 to 32 minutes after the setting.

ex : if timer 1on was set to 19:30 with the random function on, the timer will activate randomly between 19:33 to 20:03.

if timer 1off was set to 23:00 with the random function on, the timer will activate randomly between 23:02 to 23:32.

To avoid overlapping, make sure to leave a minimum of 31 minutes gap between different sets of timer.

6. Manual control

Displayed features:

ON : socket turns on.

OFF : socket turns off.

AUTO : socket turns on/off automatically via timer.

Manual ON setting

Press [ON/AUTO/OFF" button to switch from [AUTO" to [ON".

This mode allows socket of the device to power up. Power indicator will light up.

Manual OFF setting

Press [ON/AUTO/OFF" button to switch from [AUTO" to [OFF".

This mode turns socket of the device off. Power indicators will turn off.

7. Electrical parameters

Operating voltage : 230VAC

Battery : NiMh 1.2V

Power consumption : < 0.9W

Response time : 1 minute

Power output : 230VAC/16A/3680W

Q&A

Q: Why won`t my timer turn on?

A: It`s out of battery, you can charge the timer by plugging onto any power outlet. Charge the device for at least 15 minutes. Then press [RESET " button to reset the device.

Q: Can I set seconds of the timer?

A: No, the smallest time unit is minute.

Q: Does my timer keeps old settings without being plugged onto a power outlet?

A: Yes, the timer has an internal battery, it allows the timer to save settings without a power outlet.

Q: Is the battery rechargeable?

A: Yes, the battery is rechargeable. We recommend to charge it for 4 hours so the battery is fully charged.

Q: Does the timer needs internet connection?

A: The timer does not need internet.

Q: Does the screen have back light function?

A: It doesn`t support back light.

Digital Timer Socket, Timing Switch Socket, Electronic Timer Socket, Timer Socket

NINGBO COWELL ELECTRONICS & TECHNOLOGY CO., LTD , https://www.cowellsockets.com